Model NO.
ALIFPO01
Price:
US $ 5.50-6.00
Delivery:
FOB China
Country of Origin:
China
Quantity:
Place of Origin: China
Model Number: ALIFPO01
Environment Requirements:
Storage Environment
a) Temperature: -40°C~+60°C
b) Relative humidity:≤95%
c) Atmospheric pressure: 500 hPa~1060 hPa
Operating Environment
a) Temperature: 10°C~40°C
b) Relative humidity:≤75%
c) Atmospheric pressure: 700 hPa~1060 hPa


Quick Details

The pulse oxygen saturation is the percentage of HbO₂ in the total Hb in the blood, so-called the O₂ concentration in the blood. It is an important bio-parameter for the respiration. For the purpose of measuring the SpO₂ more easily and accurately, our company developed the Pulse Oximeter. At the same time, the device can measure the pulse rate simultaneously.
The Pulse Oximeter features in small vollum, low power consumption, convenient operation and being portable. It is only necessary for patient to put one of his fingers into a fingertip photoelectric sensor for diagnosis, and a display screen will directly show measured value of Hemoglobin Saturation.

1. Features
  • Operation of the product is simple and convenient.
  • The product is small in volume, light in weight( total weight is about 50g including batteries) and convenient in carrying.
  • Power consumption of the product is low and the two originally equipped AAA batteries can be operated continuously for 20 hours.
  • The product will enter standby mode when no signal is in the product within 5 seconds.
  • Display direction can be changed automatically, easy to view.
2. Major Applications and Scope of Application
The Pulse Oximeter can be used to measure human Hemoglobin Saturation and pulse rate through finger, and indicate the pulse intensity by the bar-display. The product is suitable for use in family, hospital (Ordinary sickroom), Oxygen Bar, social medical organizations and also the measure of saturation oxygen and pulse rate.

! The product is not suitable for use in continuous supervision for patients.
! The product of overrating would emerge when the patient is suffering from toxicosis which caused by carbon monoxide, the device is not recommended to be used under this circumstance.


3. Installation
1) View of the Front Panel
Front view
 
Batteries installation
Mounting the hanging rope
 
2) Battery
Step 1. Refer to Figure 3 and insert the two AAA size batteries properly in the right direction.
Step 2. Replace the cover.

! Please take care  when you insert the batteries for the improper insertion may damage the device.

3) Mounting the Hanging Rope
Step 1. Put the end of the rope through the hole.
Step 2. Put another end of the rope through the first one and then tighten it.

4. Operating Guide
1) Insert the two batteries properly to the direction, and then replace the cover.
2) Open the clip as shown in Figure 5.

3) Let the patient's finger put into the rubber cushions of the clip (make sure the finger is in the right position), and then clip the finger.
4) Press the button once on front panel.
5) Do not shake the finger and keep the patient at ease during the process. Meanwhile, human body is not recommended in movement status.
6) Get the information directly from screen display.
7) The button has two functions. When the device is in standby mode, pressing the button can exit it; When the device is in operation status, pressing the button long can change brightness of the screen.
8) The device could change display direction according to the handing direction.

! Fingernails and the luminescent tube should be on the same side.

5. Repairing and Maintenance
  • Please change the batteries when the low-voltage displayed on the screen.
  • Please clean the surface of the device before using. Wipe the device with medical alcohol first, and then let it dry in air or clean it by dry clean fabric.
  • Using the medical alcohol to disinfect the product after use, prevent from cross infection for next time use.
  • Please take out the batteries if the oximeter is not in use for a long time.
  •  The best storage environment of the device is -40°C to 60°C ambient temperature and not higher than 95% relative humidity.
  • Users are advised to calibrate the device termly (or according to the calibrating program of hospital). It also can be performed at the state-appointed agent or just contact us for calibration.
! High-pressure sterilization cannot be used on the device.
! Do not immerse the device in liquid.
! It is recommended that the device should be kept in a dry environment. Humidity may reduce the useful life of the device, or even damage it.


 